Inquire / PartsGPU-first · inquiry reference

Build the inquiry from the rack.

A parts reference for building an inquiry. Seven layers, 29 sub-parts, no public sale.

Ask about a part
The demand ladder

GPU tiers — what we're asked for

The tiers we broker, top to bottom. This is a demand list, not inventory — RackMind holds no stock.

  1. 01

    Tier 1 — B200 · B300 — Blackwell, current generation — Active demand

  2. 02

    Tier 2 — GB200 NVL72 — full-rack Blackwell systems — Active demand

  3. 03

    Tier 3 — H200 — 141GB, last-gen flagship — Lots we're originating

  4. 03

    Tier 3 — MI300X — 192GB, AMD flagship — Active demand

  5. 04

    Tier 4 — H100 — SXM5 · PCIe · NVL — Always sourcing

  6. 05

    Tier 5 — A100 80GB · A100 40GB — the workhorse tier — Lots we're originating

'Lots we're originating' = a verified seller lot in process — seller anonymous, gear never in RackMind's custody. 'Active demand' = buyers asking now. 'Always sourcing' = send us yours any time.

Selling a fleet? Name the tier in your inquiry — it's the first sort every buyer runs.

Demand list

What we're asked for

GPU fleets and current-generation cards first. If your fleet or rack holds them, start with the part number.

  • GPU Servers
    H200 / B200-class GPU modules · H100 / A100 modules · HGX baseboards · NVLink and InfiniBand optics & cables
  • Compute Servers
    current and recent Dell PowerEdge and HPE ProLiant servers · DDR4 / DDR5 ECC memory · Xeon Scalable and EPYC CPUs
  • Top-of-Rack Switch
    25G / 100G / 400G switches · transceivers and DAC cables
  • Storage
    storage chassis, backplanes, RAID / HBA controllers (never drives — see the drives promise)
  • PDUs & Power
    metered and switched rack PDUs
  • Patch Panels & Cabling
    patch panels, cable managers, fibre and copper runs
  • Rack Frame
    42U cabinets with doors, side panels, and rails

Drives are data-bearing media. RackMind never takes custody of data-bearing media — drives stay with you, or move directly to a certified processing partner for NIST 800-88 sanitization.

Seller intake

Selling? Send this.

You do not need a perfect spreadsheet. Send what you have:

  • What it is — model and part numbers (for example: H100 80GB SXM5), per item
  • How many — units, servers, racks
  • The configuration — GPUs per server, CPU, memory, storage, and networking (NVLink / InfiniBand included or not)
  • Age & history — when it entered service; new, used, or refurbished (tested, with warranty)
  • Photos — the unit and its nameplate
  • Where it is — city and state
  • Drives — drives stay with you or go to a certified processing partner; RackMind never takes custody
  • Title — that you own it, free of liens
  • Your timeline — when it needs to move

Serial numbers come after a signed agreement — counts and configs are enough to start.

Inquire
Parts reference. Inquiries only.

29 sub-parts across seven layers. GPU servers lead the reference; use it to name what is coming out, and add quantities to an inquiry. Nothing here is for sale by RackMind.

Inquiry reference
Build the inquiry

Find the part. Add it to the inquiry.

Filter the taxonomy by layer or identifier. The Qty and bulk control is the inquiry builder: selected lines travel into the Contact inquiry form. A part record is a reference, not an offer.

29 of 29 sub-parts
01

Patch Panels & Cabling

The nervous system · 4 sub-parts · reference only

Anatomy

ID / 1U/2U panel, LC or MPO couplers, loaded or empty; Cat6A keystone panels.

24 or 48-port fiber and copper termination panels.

Inquire — single

ID / 1U/2U horizontal managers, 0U vertical rings; check for cracked fingers.

Horizontal fingers and vertical rings that keep a rack serviceable.

Inquire — single

ID / OM4/OS2 trunks, MPO-12 to LC breakout, armored jacket, duplex LC connectors.

Trunks and breakouts between racks and network rows.

Inquire — single

ID / Cat6/6A cords, snagless boots, TIA-606 labels on both ends.

Cat6/6A patch cords and structured cabling.

Inquire — single
02

Top-of-Rack Switch

Where packets get expensive · 5 sub-parts · reference only

Anatomy

ID / 24–48× SFP28, 4–6× QSFP28 uplinks, redundant PSUs; Arista 7050X3 / Nexus 9300 class.

The standard ToR workhorse for current compute racks.

Inquire — single

ID / 32× or 64× QSFP28, 1U, front-to-back airflow; 7050SX3 / QFX5120 class.

Leaf and spine boxes from GPU and dense compute builds.

Inquire — single

ID / QSFP-DD800 or OSFP ports, 32× 400G, high-wattage PSUs; 7060X5 / QFX5220 class.

High-bandwidth fabric for GPU clusters.

Inquire — single

ID / SFP28 25G, QSFP28 100G, QSFP-DD 400G; check rate, reach, and coded vendor.

Transceivers are serialized, testable, and often worth more than the frame.

Inquire — single

ID / 1–5 m passive twinax, QSFP28/QSFP-DD, part number printed on the pull tab.

Passive and active twinax in short runs.

Inquire — single
03

GPU Servers

The top of the ladder · 4 sub-parts · reference only

Anatomy

ID / H200 / B200-class SXM, H100 80GB SXM5 or PCIe, A100 80GB SXM4; confirm with nvidia-smi and a serial photo.

The accelerators themselves — the reason the node matters.

Inquire — single

ID / 8-GPU HGX H200 / B200-class or H100 baseboard in a 4U chassis; NVLink fabric, air or liquid.

The 8-GPU carrier that ties SXM modules together.

Inquire — single

ID / NVLink bridges, ConnectX-6/7 HDR/NDR NICs, QSFP56/QSFP112 cables.

The fabric that makes a GPU cluster worth more than its parts.

Inquire — single

ID / 4U 8× SXM bays, 6× 3000W PSUs, high-flow fans or liquid manifolds.

The 4U shell, power, and cooling that support eight modules.

Inquire — single
04

Compute Servers

The volume layer · 5 sub-parts · reference only

Anatomy

ID / Xeon Scalable Gold/Platinum or EPYC 7003/9004; note socket count and generation.

Socketed processors with a stable secondary market.

Inquire — single

ID / RDIMM 32/64/128GB, 4800/5600 MT/s; label shows speed and rank.

Registered ECC memory, usually the easiest part to resell.

Inquire — single

ID / PCIe 4.0/5.0 x16 risers, right or left exit, 8-pin GPU leads.

Riser cages, slots, and GPU power leads.

Inquire — single

ID / 40/60/80 mm hot-swap modules; count per node and check connectors.

Hot-swap fan modules, sold as sets or spares.

Inquire — single

ID / 800–1600W redundant PSUs, Platinum/Titanium; check wattage and part number.

Matched pairs keep nodes serviceable and resellable.

Inquire — single
05

Storage

Empty bays, real value · 3 sub-parts · reference only

Anatomy

ID / 2U 12–24 bay or 4U 24–60 bay; LFF vs SFF, rail kit included.

The enclosure, bays, and rails.

Inquire — single

ID / SAS/SATA/NVMe expander backplane; inspect connectors for bent pins.

The midplane that connects every bay.

Inquire — single

ID / RAID/HBA with cache battery or supercap; model number on the bracket.

RAID and HBA cards that make a shelf usable.

Inquire — single
06

PDUs & Power

Assets and liabilities · 4 sub-parts · reference only

Anatomy

ID / 0U vertical or 1U horizontal, C13/C19 outlets, per-outlet metering, 208V.

The only power layer with a dependable secondary market.

Inquire — single

ID / 0U/1U, no metering or network port, standard C13 outlets.

Unmetered strips; count them, do not count on them.

Inquire — single

ID / Sealed lead-acid or lithium strings; check age, swelling, and local handling rules.

Often a removal line item rather than a recovery line item.

Inquire — single

ID / C13/C19 cords, L6-30P whips, locking connectors; test and count.

Cords and whips that are cheap to replace and easy to overcount.

Inquire — single
07

Rack Frame

The envelope itself · 4 sub-parts · reference only

Anatomy

ID / 600/800 mm wide, 1070/1200 mm deep; brand, door style, and keys.

Four-post frames with doors and side panels.

Inquire — single

ID / Perforated or solid doors, side panels, locks, and keys.

Complete racks with keys are worth more than bare frames.

Inquire — single

ID / Blanking panels, brush strips, cable brackets, mounting screws.

The small parts that make a used rack sellable.

Inquire — single

ID / Set of four casters or leveling feet; check threads and locking brakes.

A complete set matters more than it sounds.

Inquire — single
Need it before launch?

Tell me the part number.

Single unit or a pallet. The inquiry goes to me.

Inquire about a part